Model: UX-49A 900 series band unit REVISED 11-15-89 Division: Amateur Note: This service bulletin is meant for technical per- sonnel with experience working on solid state com- munications equipment. Damage caused by im- properly installing this modification may cause ICOM to charge for subsequent repairs to the product. ICOM does not warrant this modification. Bulletin #: 8215-001 Date: August 2, 1988 Subject: Improve PLL lock up time Information: The PLL lock up time on some units is not quick enough for all types of receivers. The problem may be worse when CTCSS is used. Operation will appear near normal when the UX-49A is operated in simples mode with no CTCSS. Procedure 1. Remove the top and bottom covers. 2. Remove the main board and replace the following components: Current New ICOM Part Part P/N C87 .1uf 35 VDC tantalum 918-01670 C97 10uf 16 VDC tantalum 918-01679 R60 100 K 1/8 watt 915-01124 R49 2.2 K 1/8 watt 915-01105 3. Add a 2.2 uf 16 VDC tantalum (ICOM P/N 918-01674) from the collector of Q15 (positive lead) to the adjacent ground (toward the edge of the board).