============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 26 MODEL: DG-1 SUBJECT: SERVICE NOTES It is our experience here in the Compton service facility that the vast majority of DG-1 problems are not component failure, but cold solder connections on the digital circuit board X54-1160-00. The second most frequent problem is dirty Molex connectors between the two circuit boards in the DG-1. Recommended service procedure: Remove both boards. Using a fine point, low wattage iron (45 or less), and a good quality low flux content solder, carefully resolder all component side connections plus the print throughs containing no components. (There are 18 of these points-only one is not accessible from the top, but is located under IC11 and can be resoldered from the bottom.) Resolder the Molex connectors. There are 9 print-thru's where solder may not have flowed thru to the component side. Using a good quality tuner cleaner with silicone lubricant, spray both boards Molex connectors and work the pins in and out 3 or 4 times to insure good contact. Rassemble and final check. Total time on the bench: 20 minutes. We will allow up to 1 hour only if in warranty.