============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 27 MODEL: TS-700A SUBJECT: REPLACEMENT OF 9V REGULATOR Replacement of the 9 volt regulator ic (MFC-4060 with MC-1723CL-A and X43-1250-00 P.C.B. This board comes complete with mounting hardware and extended leads for easy installation. PROCEDURE: 1. Remove old IC MFC4060-A Qll 2. Remove R27 1.5kohm (delete,). Replace with wire jumper. 3. Remove and reinstall R28 lkohm on foil side of P.C.B. 4. Mount P.C.B. per illustrations (observe lead call-outs between X43-1250-00, new P.C.B., and old Qll position (X43-1120-00). 5. Reset VR1 for 9.0V measured at power supply output terminal. 6. Reset VR2 for 21.0V measured at power supply output terminal.