============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 50 MODEL: TR-7600/TR-7625 SUBJECT: OPTIONAL CERAMIC FILTER Adjacent channel rejection may be improved by changing one capacitor and installing an optional narrow ceramic filter. On the TX RX unit X44-1320-10, change: * L41, CFG-455 F2 to CFL-455F * C101, from 470pF to .001uF Old part L41 L72-0309-05 CFT-455 F2 New part L41 L72-0306-05 CFL-455 F Please annotate your service manual.