============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 59 MODEL: RM-76 SUBJECT: BATTERY BACK-UP POWER To retain memory in the RM-76, an optional DC Cable and user- supplied battery may be used. This would be useful when transferring the unit Base to Mobile, or when operating on an AC supply which cannot be run continuously. Connect a DC Cable assembly, E30-0220-05, as illustrated, This will connect at the RM-76 rear panel. Battery recommendation is 7.5V DC. Current drain is less than 50mA at memory on. (1) RED ------------------------- DO NOT USE (2) BLACK------------------------- GROUND OR NEGATIVE (3) YELLOW------------------------ PLUS 7.5 VOLTS ------- | 2 1 | | | | 3 | ------- PLUG