============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 803 MODEL: TS-180S SUBJECT: CW DELAY DURING VOX MEMORY OPERATION Some operators may report missing the first dit during CW VOX operation on the memories. This will occur only in early units, and may be improved by changing one capacitor in the DFC. On the DFC VCO unit X50-1550-00, check C3 at the base of Q3. If C3 is a 22uF electrolytic, change to a .01uf disc. No adjustments are necessary.