============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 837 MODEL: TS-830S SUBJECT: OPARTION ON 240 VOLTS To operate the TS-830S on 240V AC, the power transformer split primaries must be rewired from parallel to series connection 1. Unplug the AC power cable. 2. Remove the bottom cover. 3. Remove the jumper wires between the two 0 terminals and two 120 terminals on the bottom of the power transformer. 4. Connect the adjacent 120 and 0 terminals at the middle of the transformer. This will provide 240V AC operation. For 220V AC operation, connect the adjacent 100 to 0 winding. 5. Change the AC fuse from 6A to 4A. Tag the power cord at the back of the radio to indicate that the transformer is strapped for 240V AC, and the power fuse should be 4A, and not 6A. 6. Replace the bottom cover and reconnect power to verify your work.