============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 844 MODEL: TS-120S SUBJECT: TX OSCILLATION (SUPERCEDES 821) The TS-120S may exhibit intermittent oscillation on the 15M, 10M, and/or 20M bands. Symptoms may be no control of Carrier level, full current or ALC in either CW or SSB after initial keying or modulation, or "full output both forward and reflected". 1. Physically disconnect power form the radio. 2. Make certain the Antenna fitting is tight to the rear panel. 3. Remove covers. Unplug speaker lead. 4. Check for loose screws securing the RF unit X44-1260-01 and the relay unit X41-1250-00 (located over the RF unit). 5. On the RF unit, check diodes D2,3 and 8 for high reverse leakage. If in doubt, replace. 6. I not already present on the RF unit, make the following chanqes: R47 (33 OHMS change to 10 OHMS Radial (RD12CY2ElOOJ) R50 (560 OHMS) change to 680 OHMS Radial (RD12CY2E681J) C61 (22OPF) Remove Add 2 lS1587 (V11-0370-05) diodes in series, anode to ground from the junction of C4 and D8. NOTE: Diode I.D. lS1587 = lS1585 Added diodes may induce RX IMD. If so delete. 7. As illustrated, carefully cut the cable ties on the wire harness (without cutting the wires) as it rounds the corner behind the PLL unit X50-1490-00. 8. Seperate the AVB line, a white/brown line from the filter unit X51-1200-00 to the RF unit X44-1260-01 9. Adjacent to the rear of the PLL and to the left you will see a five pin terminal strip. The two right-hand most terminals are bridged. WITHOUT BREAKING THE TERMINAL OR STRIP, remove the heavy yellow, and light red and green lines and transfer them to the adjacent terminal. There will now be seven lines, plus the positive end of Cl on the second terminal. Be sure to cut the wire jumper between these two terminals. 10. The free terminal will be a tie point for the AVB line bypass capacitor. Solder a .01pF 50V disc ceramic (C52-1710-36) between ground and the first free terminal. Use spaghetti to insulate the leads. Then solder the AVB line to the .01pF cap. 11. Retie the cable harness with nylon cable ties (J61-0401-05). 12. Replace the covers and speaker lead. Power-up and verify correct operation. NOTE: Installation time for this procedure is approximately 1/2 hour.