============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 900 MODEL: TS-940S SUBJECT: PLL Unlock Some users of the TS-940S have reported a blanking of the display accompanied by a loss of transmit and receive. Re-adjustment of the PLL unit will correct this tendency. PROCEDURE: On the PLL unit 1. Set the dial frequency for approximately 1.8 MHz (inside the band) 2. Using an RF probe at TP5 adjust L22, L23, and L24 for a maximum reading on the meter. You should see approximately 250mv. 3. Adjustment of L24 will produce the greatest change, which may be up to a 90 degree adjustment from its present position. Time required for this modification is 1/2 hour or less.