============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 1020 MODEL: TS-950 SUBJECT: Infinite SWR at Beginning of Transmission Symptom: During "Full Break-in" operation the SWR meter shows infinite SWR at the beginning of transmit. This results in a reduction of the transmitter power, followed by a gradual increase to normal full power. This symptom does not occur with the antenna tuner set to "THRU". Cause: Normally the RXB line should be 0 vdc at the beginning of transmit operations. We have found that this does not always occur. The length of time required for transmit power to return to normal is directly related to the time constant of capacitor C128 on the RXB line. Corrective Action: Removing this capacitor corrects the above symptom, but might affect the receiver sensitivity at a dial frequency of 100 kHz. Remove capacitor C128 on the RF Unit (X44-3100-00). DO NOT MODIFY THE UNIT IF THE SYMPTON IS NOT PRESENT. ----------------------------------------------------- Caution: This modification requires soldering equipment rated for CMOS type circuits. It also requires familiarity with surface mount soldering techniques. If you do not have the proper equipment or knowledge do not attempt this modification yourself. Seek qualified assistance. Time required for this modification is 30 minutes or less. Service Code:A:43 B:X44-3100 C:C128 D:91