============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 1055 MODEL: All SUBJECT: Power Module Heat Sink Compound Symptom: Several current and past model transceivers do not use Heat Sink Compound on the power modules. Our engineering department determined through testing, that those models with fine castings or machined areas under the power module do not really require its use. Several service facilities and customers have questioned this and are concerned that this could eventually cause failure of the power module(s). Corrective Action: In order to ameliorate any anxiety and to increase your confidence, our engineers recommend that you use Silicone Heat Compound whenever replacing any of these devices or whenever they must be lifted for service of other components on the board. Our production lines will begin using this compound again as added protection for these devices. Parts Required: Silicone Heat Sink Compound W01-0411-05