MsgNo: 52623 From: JE1RLA@JA1WOI Date: 22-Apr/05:31 Subject: G3RUH modem <-> TM531(to PE1KHX) Times Read: 1 The terminal is connected to slider of VR3(Max. deviation adjast) through through C55(1uf). You can discriminate the terminal of VCO from VR3. TXA ----/\/\/\--II---------- MO VCO 56kohm 0.1uF If you get weary to remove a shielding plate, you may connect TXA to hotend of VR3 through R and C as aforesaid. 2. RXA connect to pin 12 of IC2. IC2 is a hybrid IC for FM IF amp. and detector. The IC was not indicated the number of pin. You must discriminate the pin from granded pin of IC. 2 and 16(last) pin is connected to grand. I connect 2 TNCs to this tranceiver. One is 9600bps and oter is Bell 202,1200bps. Tow modems are running without any troubles. Sammy JE1RLA @je1rla