Radiofrequency Radiation Dosimetry Handbook - Fourth Edition

Table 10.1 Thermoregulatory Characteristics of Animals

Body Temp. (C°) Thermo- regulatory Mechanisms
Thermo -
Thermo -
Air-
Survival
Temp.
Limits (C°)
Species Normal Min. Max. Sweating Shivering Panting preferenduma (C°) neutral Zone (C°) Low High
Man*b 37 27 42 Yes Yes No 23-26 25-28 0 50
Homo sapiens (50% RH)
Rhesus monkeyc 38-39 25 43 Yes Yes No --- 25-31 --- 40
Macaca mulatta
Patas monkeyd 38-40 --- 42-43 Yes Yes No --- 20-40 <0 >55
Erythrocebus patas
Squirrel monkey3 38-39 25 43 Yes Yes No 35-36 25-35 0 40
Saimiri sciureus
Dog f 38-39 24 42 No Yes Yes 12-16 18-25 -80** 42-58
Canis familiaris
Cat g 38-39 19 42 No Yes Yes --- 32-38 -10 41
Felix domesticus
Domestic pig h 36.5-37 --- 42 No Yes Yes 30-32+ 15-27 -27 35
Sus scrofa
Sheep (fleeced) h 38-39 --- 42 Yes Yes Yes --- 10-20 -45 32
Ovis aries
Rabbit i 39 20 42 No Yes Yes --- 15-25 -29 32
Oryctolagus cuniculus
Guinea pig i 39 17 43 No Yes Yes 29 30-31 -15 32
Cavis porcellus
Rat jk 37-38 20 42 No Yes No 29-30 28-30 -3 40
Rattus norvegicus
Mouse j 37 20 42-44 No Yes No 32 30-33 -5 37
Mus musculus



* Assumes man is lightly clothed, sedentary in still air.
** Value for Alaskan husky is well below that for most other subspecies.
Values given are for young animals.
a Cabanac, M. (1983)
b Elizondo, R. (1977)
c Johnson, G.S., and Elizondo, R.S. (1979)
d Mahoney, S. (1980)
e Stitt, J.T., and Hardy, J.D. (1971)
f Adams, T.C. (1971)
g Adams, T., et al. (1970)
h Whittow, G.C. (1971)
i Gonzalez, R.R., et al. (1971)
j Hart, J.S. (1971)
k Berry, J.J., et al. (1984)

This is a Department of Defense computer system for authorized use only. DoD computer systems may be monitored for all lawful purposes, including to ensure that their use is authorized, for management of the system, to facilitate against unauthorized access, and to verify security procedures, survivability, and operational security. Using this system constitutes consent to monitoring. All information, including personal information, placed on or sent over this system may be obtained during monitoring. Unauthorized use could result in criminal prosecution.