Table 9.1. Summary of Electric-Current Effects on Humans (Guy and Chou, 1982)

Electric Shock Gender 0.06-kHz Current
(mA)
10.0-kHz Current
(mA)
Spark Discharge
Energy
No sensation Men
0.4
7
in hand Women
0.3
5
Threshold of Men
1.1
12
0.12mJ
perception Women
0.7
8
C=1000 pF
V=350 V
Shock - Men
1.8
17
0.5-1.5 mJ
not painful Women
1.2
11
C=1000 pF
V=0.7-1.2 kV
Painful shock; Men
9.0
55
muscle control Women
6.0
37
Children
5.0
27
Painful shock; Men
16.0
75
let-go threshold Women
10.5
50
Severe Men
23.0
94
shock Women
15.0
63



Threshold for radiofrequency burns: 200 mA

This is a Department of Defense computer system for authorized use only. DoD computer systems may be monitored for all lawful purposes, including to ensure that their use is authorized, for management of the system, to facilitate against unauthorized access, and to verify security procedures, survivability, and operational security. Using this system constitutes consent to monitoring. All information, including personal information, placed on or sent over this system may be obtained during monitoring. Unauthorized use could result in criminal prosecution.