Radiofrequency Radiation Dosimetry Handbook - Fourth Edition

Table 9.10. Threshold Currents For Perception When In Grasping Contact With The Brass-Rod Electrode And Threshold External Electric Fields For Perception When In Contact With A Compact Car (Cg = 800 pF)
(Gandhi et al., 1984)

Frequency
(kHz)
Threshold Current *
mA
Threshold External E-Field
V/m
10 12.5 870
30 45.0 1036
100 315.0 2246
300 NA
1000 NA



* Average of values for two subjects;

NA -- The threshold currents are higher than currents available from the Krohn-Hite model BR7500, 75-W amplifier.

This is a Department of Defense computer system for authorized use only. DoD computer systems may be monitored for all lawful purposes, including to ensure that their use is authorized, for management of the system, to facilitate against unauthorized access, and to verify security procedures, survivability, and operational security. Using this system constitutes consent to monitoring. All information, including personal information, placed on or sent over this system may be obtained during monitoring. Unauthorized use could result in criminal prosecution.