Radiofrequency Radiation Dosimetry Handbook - Fourth Edition

Table 9.6. Measuared Body Currents [mA/ (kV/m) ] To Ground For Subjects Exposed Under Different Conditions To 24.8-kHz VLF Electric Fields [Washington VLF (Guy and Chou, 1982) ]

Condition and E-Field
Strength (Wet Asphalt)
Hands Down One Hand Up Both Hands Up Crouch
E = 487 V/m
Bare feet
Subject No. 1
(height = 1.77 m) 6.0 7.23 8.19 3.14
Subject No. 2
(Height = 1.77 m) 5.6 6.80 7.62 2.77
Subject No. 3
(Height = 1.68 m) 5.24 6.30 7.02 2.46
Rubber-sole shoes
Subject No.1 3.20 3.72 4.00 1.46
Subject No. 2 3.78 4.44 4.93 1.56
Subject No.3 2.6 3.10 3.39 1.21
Leather-sole shoes
Subject No. 1 4.52 5.46 5.91 2.34
Feet grounded to ground strip
Subject No. 3 5.9 - - - - - -
Feet insulated, hand
grounded to ground strip
6.63 - - - - - -
E = 1.46 kV/m
Subject No. 2 6.44 7.67 8.70 2.95

This is a Department of Defense computer system for authorized use only. DoD computer systems may be monitored for all lawful purposes, including to ensure that their use is authorized, for management of the system, to facilitate against unauthorized access, and to verify security procedures, survivability, and operational security. Using this system constitutes consent to monitoring. All information, including personal information, placed on or sent over this system may be obtained during monitoring. Unauthorized use could result in criminal prosecution.