PRO-94 Tutorial: Limit Search

A Limit Search lets you search with a specific range of frequencies. -L- appears during a limit search. This tutorial will show you how to set a low frequency and high frequency and then search between those frequencies. Our example shows a search between 822.7375 MHz and 867.8875 MHz.

For additional information on this product, see the links below:

Step 1: Enter Programming Mode
 
BankA-1ch-866.1625-PGM Pro94-keypad-PROG
 
Press PROG. PGM will appear on the display.
 
Step 2: Set the Lower Limit
 
Lo-29000-PGM Pro94-keypad-SRC(LIMIT)
 
Press LIMIT (SRC)Lo and 29.000 MHz (or the previous low limit frequency) will appear on the display. 29.000 MHz is the low end of the scanner's range.
 
Step 3: Enter the Low Frequency
 
Lo-822.7375-PGM Pro94-keypad-SVC(E)-numberpad
 
Using the number pad, enter the frequency that is the lower limit of the range you want to search (including the decimal point). Press E (SVC). In this example, the low frequency is 822.7375.
 
Step 4: Set the Upper Limit
 
Hi-1300.000-PGM Pro94-keypad-SRC(LIMIT)
 
Press LIMIT (SRC). Hi and 1300.000 MHz (or the previous high limit frequency) appear. 1300.000 MHz is the upper limit of the scanner's range.
 
Step 5: Enter the High Frequency
 
Hi-867.8875-PGM Pro94-keypad-SVC(E)-numberpad
 
Using the number pad, enter the frequency that is the upper limit of the range you want to search (including the decimal point). Press E (SVC) again. In this example, the high frequency is 867.8875.
 
Step 6: Select the Search Direction
 
L-867.8375-SEARCH Pro94-keypad-UP-DOWN
 
Press the DOWN arrow key to search from the upper to the lower limit, or the UP arrow key to search from the lower to the upper limit.  -L- will appear on the display. In this example, we have pressed down to search from the upper limit to the lower limit.
 
Step 7: Stop on a Transmission
 
L-867.6625-HOLD-SEARCH Pro94-keypad-A/BHOLD
 
When the scanner stops on a transmission, quickly press HOLD (A/B) to stop searching and listen to the transmission. HOLD will appear on the display. In the example above, we have stopped on frequency 867.6625 MHz.
 
Step 8: Store in Monitor Memory
 
L-867.6625-HOLD-SEARCH Pro94-keypad-MON/CLR
 
With the scanner in HOLD mode, press MON/CLR (.) to store the displayed frequency into the current monitor memory.
 
Step 9: Search for Additional Frequencies
 
L-866.8375-SEARCH Pro94-keypad-UP-DOWN
 
To continue searching, press HOLD (A/B) or the UP or DOWN arrow key for at least 1 second. If you didn't press MON/CLR (.), simply press the UP or DOWN arrow key.
 
Step 10: Exit Limit Search Mode
 
BankA-1ch-866.1625-MAN Pro94-keypad-MAN
 
Press MAN. This will return you to manual mode.
 

Copyright© RadioShack Corporation 2002. All rights reserved.

Privacy Policy